AQUA Hydro Physical Systems
Exterminate and Prevent Biological Contamination
Installation
and operation instruction K0-Junior
-
open water circuits
The
delivery include (please check):
- Installation
and operation instruction K0 Junior K0-Junior in cabinet
- with
pump, incl. 180 ° outlet pipe
- Pump
description
- Installation
and operation instruction K0 Junior
Installation (Photo 1)
- Remove
the thread protection on in- (2) and outlet (1) and connect by
pipelines/hoses to the water supply.
- Fill
up the pump with water, as described in the manual
- After
filling only, turn on pump power supply 220/ 240 V Photo 1
Photo1

Installed connections
- Water
inlet to pump (Photo 1/ No. 2) : Inside threads R 1 1/4
- Water
outlet (Photo 1/ No. 1) : External threads ISO 7 R 3/4
(180 ° outlet pipe)
- Air
inlet (Photo 2/ No. 3) : Inside threads 1/4 (attached to
the reactor bottom)
- Secure to fill-up the pump before start of operation (as
described in the pump manual).
Photo2
Adjustment already set by the manufacturer
if however required:
Outlet adjustment unit (Photo
3):
- To adjust the
outlet, loosen the lower contra thread nut. (Photo 3/
No. 1, TS/SW 32-nut).
- Turn then the
upper nut tight into the adjustment unit and then slowly
back until a clear air beam is visible inside the above pipe
(Photo 3/ No. 2 TS/SW 32-nut).
- Secure that the AQUA HP-SYSTEM has
a constant free and unrestricted outlet operation, without
any pressure loss.
Photo3
Disassemble
After disassemble, empty the AQUA HP-SYSTEM
and pump and replace the protection cowers on the in- and outlets.
Subject to technically improvements, this description may be changed
accordingly.
Updated: 24.09.03