Click the Aqua Correct Logo. Water conditioning and lime scale treatment. Water surface tension reduction. Hard water descaler
Physical Water Conditioning Technic
 
Nielsen Technical Trading
P.O.Box 10, DK-4621 Gadstrup, Denmark
Telephone: (+45) 46 19 09 90      Fax: (+45) 46 19 09 70
aqua-correct@aqua-correct.dk
Click the Aqua HP-Systems Logo. Hydro physical water purification. Kill all bacteria's, algae, spores and other organic organism

Home page Why select AQUA products Important info about water treatment Application index Technical documents Product specifications NEW: AQUA Hydro Physical Systems Quality statement Sales and product support

AQUA CORRECT water conditioners are European Technical Approved European Technical Approval and ISO 9002 Certified ISO 9001 certificate

Cooling Tower Water Conditioning - Installation and Operation Instructions:

Installation: The installation of AQUA CORRECT system is performed into the water supply pipe. The AQUA CORRECT capacity type shall be selected for full conditioning of the maximum water flow. There is no demand to flow direction, horizontal or vertical installation. The draining outlet pipe from the cooling tower must be connected to the lowest point of the water tank and the size of the pipe must secure effective removal of impurities, (min. 1 1/4" pipe) with fall toward ground.

The draining shall be valve controlled by the installation of a conductivity sensor connected to an automatic processor (range: 0 to approx. 2000 m Siemens/cm) with upper and lower output limits.

Operation instructions: The draining of upconcentrated mineral salts and impurities is an integrated part of the treatment procedure and performance guarantee. It is depending on the amount of evaporated water and the water hardness. The conductivity in the water shall normaly not exeed the value of 1200 m Siemens/cm (approx. 37 0dH = 660 ppm).

In accordance with the American CTI-standard (USA) and the equal German VDI-DIN 1947- recommandations shall, in relation to evaporated water (Wwo), a constant sufficient draining of the upconcentrated minerals (Wwa) follow and be replaced by new conditioned water (Wwz). The recommended values are:

-Wwo: 0,15 x K (cooling area) x V (amount of water) /100 = m3/h for open circuits.

-Wwo: 3,60 x Q (cooling effect kW) /2500 = m3/h for closed circuits.

-Wwa: = Wwo (max. standard value, but depending on the concentration velocity)

-Wwz: Wwa+ Wwo = m3/h (generel, + or - % local depending)

IMPORTANT!

The physical AQUA CORRECT conditioning of the water supply replaces the use of all softening units and previously chemical dossage. In case of chemical use for removal of algea, the dosage may be reduced in accordance with the 8-10% reduced water surface tension. If using chemicals, any reactions, disposals or corrosion is the responsibility of the supplier of the chemicals only. Replace all water and use only AQUA CORRECT system conditioned water at first time start up!

Static voltage tension potencials, f. inst. frictional electricity by the use of PVC tubes, may cause lime disposals in all systems and are excluded from the treatment guarantee.

WORKING CONDITIONS

During the disolving of existing disposals it shall be expected that loosen substances, which can not pass through nozzles, repeated must be removed manualy. Dissolved substances may increase the pH values and form impurities on the conductivity sensor electrodes. Regular control of the electrodes and the draining function is required according to local conditions.

GUARANTEE

The performance guarantee is related to above conditions being followed. The AQUA CORRECT guarantee is valid for the described function for a period of 6 month, provided duly payment of the AQUA CORRECT system supplied. The material substaining guarantee is 5 years.

Related subject web page link:

 Cooling tower, AQUA CORRECT physical water conditioning application results

 Cooling tower installation with automatic conductivity controler draining system

The properties of water with a reduced surface tension

 THE UNIQUE CHEMICAL FREE TECHNIC, SAFE FUNCTION AND NO PRESURE LOSS. A LOOK INSIDE THE AQUA CORRECT GUARANTEE A FULL FREE, SMOOTH LIQUID FLOW. THE OFFICIAL FUNCTION TEST REPORTS BY SCIENTIFIC INSTITUTES ARE WORLDWIDE AVAIBLE. MATERIALS: THE BEST QUALITY ACID-DURABLE ASTM A 316Ti STAINLESS STEEL.

The AQUA CORRECT unique physical features: Internal free flow - No pressure loss - No turbulence

NIELSEN TECHNICAL TRADING ApS - P.O.Box 10
DK-4621 Gadstrup - Denmark
nielsen@nielsen.dk

Design: www.wwwService.dk - Latest update 08-01 - Copyrights: NTT Watertechnic Consults & Co., Roskilde, Denmark.